Electrical Inspection Information
What electrical inspections are required for my
Electrical Permit?*
Washtenaw County Building Department enforces the 1999
NEC (National Electrical Code) with State Part 8 Amendments.
Inspections include:
-
Temporary service
-
Permanent service
-
Underground, before covering
-
Rough, before any work is covered**
-
Final
*Trade inspections can be done in conjunction with another
inspection on the same permit without an extra fee. For example more than
one inspection can be performed per trip and the cost will be the same as
one inspection. The fee is charged per trip.
**Most manufactured homes only require permanent service and
final inspections, because they have been approved at the factory.
Exception: Work to the manufactured unit that has been field installed and
will be covered must have a rough inspection.
What are common violations noted during Electrical
Inspections?
-
Permanent service; too much conduit or cable inside of building, 5
foot or less. Article 230-70 (A)
-
Firestopping; upper / lower plates and cold air returns that wires pass
through. Article 300 - 21
-
Wires running with cold air returns not sleeved. Article 300 - 22 (C)
-
Spacing of outlets 6 foot and 12 foot Rule. Article 210-52 (1) (2)
-
Spacing of outlets kitchen counter tops 24" and 48" Rule. Article 210-52
(C) (1)
-
Outlets installed on peninsula and island space. Article
210-52(C)(2)(3)(4)
-
Access for pumps on Jacuzzi type bathtubs, shall be accessible without
damaging the building finish. Article 680-72
-
Outlets that need to be GFI (Ground Fault Interrupted) Protected.
-
-
All kitchen counter plugs.
-
All accessible outlets in garage.
-
Exterior outlets.
-
Outlets in unfinished basements.
-
Bathroom outlets.
-
Outlets within 6 foot of wetbar.
-
Depth of underground cable or conduit. Table 300-5
-
Closet lights location to shelves; 6" from shelves for
fluorescent, 12" from shelves for incandescent.
For More Information: